 INNOLUX DISPLAY CORPORATION
LCD MODULE
S P E C I F I C AT I O N
www..com
Customer: Model Name: SPEC NO.: Date: Version: AT070TN83 V.1 A070-83-TT-11 2007/05/11 01
Preliminary Specification Final Specification Option AT070TN83 V.1 LCM (TTL T-con with LED Driver)
For Customer 's Acceptance Approved by Comment
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
InnoLux copyright 2004 All rights reserved, Copying forbidden.
Record of Revision
www..com
Version
Revise Date Page Initial release.
Content
Pre. Spec. 01 2006/12/05 02 2007/03/05 2 3 6 16 18 Final-spec.01 2007/05/11 1 5
Add Note 1,2,3 Modify TTL connector model from "FH19S-40S-0.5SH" to "FH19SC-40S-0.5SH" Add Note 4 Add " I: input, O: output, P: power" Add "Backlight Driving Conditions" Add Note 4 Modify TTL connector model in the Mechanical Drawing Modify backlight power consumption from "1.728W" to "2.500W". Modify panel power consumption from "0.990W" to "0.825W". Add the Max.value of VLED. Modify the Typ.value of Icc from"300mA" to "250mA" and Max.value from"350mA" to "300mA". Modify "IL" to "ILED" and the value from "180mA" to "500mA". Add Max.value of ILED. Add Note 2,Note 3. Modify Note 5. Modify test condition 1. Modify Note 6. Add the weight of corrugated board.
6
12 14 19
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
Contents
1. General Specifications ............................................................................................................ 1
www..com
2. Pin Assignment....................................................................................................................... 2 3. Operation Specifications ......................................................................................................... 5 3.1. Absolute Maximum Ratings.............................................................................................. 5 3.2. Typical Operation Conditions ........................................................................................... 6 3.3. Power Sequence ............................................................................................................. 7 3.4. Timing Characteristics ..................................................................................................... 8 3.4.1. Timing Conditions.................................................................................................... 8 3.4.2. Timing Diagram ..................................................................................................... 10 4. Optical Specifications............................................................................................................ 12 5. Reliability Test Items ............................................................................................................. 16 6. General Precautions ............................................................................................................. 17 6.1. Safety ............................................................................................................................. 17 6.2. Handling ......................................................................................................................... 17 6.3. Static Electricity .............................................................................................................. 17 6.4. Storage ........................................................................................................................... 17 6.5. Cleaning ......................................................................................................................... 17 7. Mechanical Drawing ............................................................................................................. 18 8. Package Drawing ................................................................................................................. 19 8.1. Packaging Material Table ............................................................................................... 19 8.2. Packaging Quantity ........................................................................................................ 19 8.3. Packaging Drawing ........................................................................................................ 20
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX 1. General Specifications
www..com No.
SPEC NO.: A070-83-TT-11 PAGE: 1/20
Item
Specification 7.0 inch(Diagonal) a-Si TFT active matrix 800X3(RGB)X480 Normally white, Transmissive 0.0635(W)X0.1905(H) mm 152.4 (W)X91.44 (H) mm 165(W)X104(H)X5.5(D) mm Anti-Glare RGB-stripe Digital(TTL) 2.500W(Typ.) 0.825W(Typ.) 130g (Typ.) Note 3 Note 2 Note 1
Remark
1 2 3 4 5 6 7 8 9 10 11 12 13
LCD size Driver element Resolution Display mode Dot pitch Active area Module size Surface treatment Color arrangement Interface Backlight power consumption Panel power consumption Weight
Note 1: Refer to Mechanical Drawing. Note 2: Including T-con Board power consumption. Note 3: Including LED Driver power consumption.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX 2. Pin Assignment
www..com
SPEC NO.: A070-83-TT-11 PAGE: 2/20
TFT LCD Panel Driving Section
TTL Connector is used for the module electronics interface. The recommended model is FH19SC-40S-0.5SH manufactured by Hirose. Pin No. Symbol VLED VLED ADJ GLED GLED VCC VCC MODE DE VS HS GND B5 B4 B3 GND B2 B1 P P I P P P P I I I I P I I I P I I I/O Function Power voltage for LED Driver Power voltage for LED Driver Adjust the led brightness with PWM Pulse Ground for LED circuit Ground for LED circuit Power voltage for digital circuit Power voltage for digital circuit DE or HV mode control Data enable Vsync signal input Hsync signal input Power ground Blue data input (MSB) Blue data input Blue data input Power ground Blue data input Blue data input Note 3 Note 1,2 Remark
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 B0 GND G5 G4 G3 GND G2 G1 G0 GND R5 R4 R3 GND R2 R1 R0 GND DCLK GND L/R U/D I P I I I P I I I P I I I P I I I P I P I I Blue data input(LSB) Power ground Green data input(MSB) Green data input Green data input Power ground Green data input Green data input Green data input(LSB) Power ground Red data input(MSB) Red data input Red data input Power ground Red data input Red data input Red data input(LSB) Power ground Sample clock Power ground Select left or right scanning direction Select up or down scanning direction
SPEC NO.: A070-83-TT-11 PAGE: 3/20
www..com
Note 4 Note 4
I: input, O: output, P: power
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
SPEC NO.: A070-83-TT-11 PAGE: 4/20
Note1: ADJ adjust brightness to control Pin,Pulse duty the bigger the brighter.
www..com
Note 2: ADJ signal=0~3.3V;Operating frequency:100~300Hz.
Note 3: DE Mode: Mode="H", HS floating and VS floating. HV Mode: Mode="L" and DE floating. Note 4: Selection of scanning mode Setting of scan control input U/D GND VCC GND VCC L/R VCC GND GND VCC Up to down, left to right Down to up, right to left Up to down, right to left Down to up, left to right
Scanning direction
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX 3. Operation Specifications
3.1.
www..com
SPEC NO.: A070-83-TT-11 PAGE: 5/20
Absolute Maximum Ratings
Values Item Symbol Min. VCC -0.3 -0.3 -20 -30 Max. 6.0 5.5 6.3 70 80 V V V Unit Remark
Power voltage VLED Input signal voltage Operation Temperature Storage Temperature VI TOP TST
Note: The absolute maximum rating values of this product are not allowed to be exceeded at any times. A module should be used with any of the absolute maximum ratings exceeded, the characteristics of the module may not be recovered, or in an extreme condition, the module may be permanently destroyed.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
3.2. Typical Operation Conditions
Values
www..com
SPEC NO.: A070-83-TT-11 PAGE: 6/20
Item
Symbol Min. VCC 3.1 4.8 0.7VCC 0 20,000 Typ. 3.3 5.0 250 500 Max. 3.5 5.2 300 550 VCC 0.3VCC -
Unit
Remark
V V mA mA V
Note 1 Note 2
Power voltage VLED Icc Current consumption ILED Input logic high voltage Input logic low voltage LED life time VIH VIL Note 3
Note 4 V Hr Note 5
Note 1: VCC setting should match the signals output voltage (refer to Note 4) of customer's system board. Note 2: LED driving voltage. Note 3: LED driving current. Note 4: DCLK,DE, HS, VS, R0~ R5,,G0~ G5,B0~ B5. Note 5: The "LED life time" is defined as the module brightness decrease to 50% original brightness at Ta=25 and VLED=5.0V. The LED lifetime could be decreased if operating VLED is larger than 5.0V.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
3.3. Power Sequence
www..com
SPEC NO.: A070-83-TT-11 PAGE: 7/20
Power Supply Vcc
Data Signal
t1
B/L
t2
t3
t1
t1 50 mSec t2 200 mSec t3 200 mSec Note: Data Signal includes DCLK, DE, HS, VS, R0~ R5, G0~ G5, B0~ B5.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
3.4. Timing Characteristics
3.4.1. Timing Conditions
www..com
SPEC NO.: A070-83-TT-11 PAGE: 8/20
SYNC mode Input signal characteristics ( 800 x 480 ) Values Item Symbol Min. Clock Period Clock Frequency Clock Low Level Width Clock High Level Width Clock Rise/Fall Time HSYNC Period HSYNC Pulse Width HSYNC Back Porch HSYNC Width + Back Porch Horizontal valid data width HSYNC Front Porch Horizontal Blank VSYNC Period VSYNC Pulse Width VSYNC Back Porch Vertical valid data width Vertical Front Porch Vertical Blank Data Setup Time Data Hold Time tCLK fCLK tWCL tWCH tCLKr, tCLKf tHP tHW tHBP thw + tHBP tHV tHFP tHBK tVP tVW tVBP tw tVFP tVBK tDS tDH 5 10 20.0 8 8 Typ. 30.0 33.3 928 48 40 88 800 tHP - tHW - tHBP - tHV tHP - tHV 525 3 29 480 tVP - tVW - tVBP - tw tVP - tw Max. 50 3 tCLK tCLK tCLK tCLK tCLK tCLK tCLK tHP tHP tHP tHP tHP tHP ns ns ns ns MHz Unit Remark
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
DE mode Input signal characteristics ( 800 x 480 ) Item
www..com
SPEC NO.: A070-83-TT-11 PAGE: 9/20
Values Symbol Min. Period Frequency Low Level Width DCLK High Level Width Rise/Fall Time Duty Setup Time Hold Time Rise/Fall Time Horizontal Period DE Horizontal Valid Horizontal Blank Vertical Period Vertical Valid Vertical Blank Setup Time DATA Hold Time Rise/Fall Time tWCH tCLKr, tCLKf tDES tDEH tDEr, tDEf tHP tHV tHBK tVP tw tVBK tDS tDH tDr, tDf 5 10 6 0.45 5 10 0.50 928 800 tHP - tHV 525 480 tVP - tw 3 ns tHP 3 0.55 16 tCLK ns tCLKL/ tCLK ns tCLK fCLK tWCL 20.0 6 Typ. 30.0 33.3 Max. 50 ns MHz Unit Remark
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
3.4.2. Timing Diagram
SPEC NO.: A070-83-TT-11 PAGE: 10/20
www..com
Input Vertical Timing
tH P
H sync
tH B P tH W tH V tH F P
DE
tH B K
Input Horizontal Timing
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
SPEC NO.: A070-83-TT-11 PAGE: 11/20
www..com
tDEr(t Dr) DE(RGB Data)
0.7VDD 0.3VDD
tDEf(tDf)
DE and RGB Input Timing
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX 4. Optical Specifications
www..com
SPEC NO.: A070-83-TT-11 PAGE: 12/20
Values Item Symbol Condition Min. L Viewing angle (CR 10) R T B TON Response time TOFF Contrast ratio Color chromaticity CR WX WY L YU Normal ==0 400 0.26 0.28 250 70 15 500 0.31 0.33 300 75 30 0.36 0.38 msec Cd/m2 % Note 3 Note 4 Note 2 Note 5 Note 6 Note 6 Note 7 =180(9 o'clock) =0(3 o'clock) =90(12 o'clock) =270(6 o'clock) 60 60 40 60 Typ. 70 70 50 70 10 Max. degree 20 msec Note 3 Note 1 Unit Remark
Luminance Luminance uniformity
Test Conditions: 1. VCC=3.3V, VLED=5.0V.The ambient temperature is 25. 2. The test systems refer to Note 2.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
Note 1: Definition of viewing angle range Normal line ==0
www..com
SPEC NO.: A070-83-TT-11 PAGE: 13/20
=90 12 o'clock direction L B R
T
=180 Active Area LCM =270 6 o'clock direction Fig. 4-1 Definition of viewing angle
=0
Note 2: Definition of optical measurement system. The optical characteristics should be measured in dark room. After 30 minutes operation, the optical properties are measured at the center point of the LCD screen. (Response time is measured by Photo detector TOPCON BM-7, other items are measured by BM-5A/Field of view: 1 /Height: 500mm.) Normal line ==0 Photo detector =90 12 o'clock direction
500mm
=180
Active Area
=0
LCM =270 6 o'clock direction Fig. 4-2 Optical measurement system setup
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
SPEC NO.: A070-83-TT-11 PAGE: 14/20
Note 3: Definition of Response time The response time is defined as the LCD optical switching time interval between "White" state and "Black" state. Rise time (TON) is the time between photo detector output intensity changed from 90% to 10%. And fall time (TOFF) is the time between photo detector output intensity changed from 10% to 90%. www..com White (TFT OFF) Photo detector output (Relative value) 100% 90% Black (TFT ON) White (TFT OFF)
10% 0% TON Fig. 4-3 Definition of response time TOFF
Note 4: Definition of contrast ratio
Luminance measured when LCD on the " Black" state Note 5: Definition of color chromaticity (CIE1931) Color coordinates measured at center point of LCD. Note 6: All input terminals LCD panel must be ground while measuring the center area of the panel. The LED driving condition is VLED=5.0V. Contrast ratio (CR) = Luminance measured when LCD on the " White" state
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
SPEC NO.: A070-83-TT-11 PAGE: 15/20
Note 7: Definition of Luminance Uniformity Active area is divided into 9 measuring areas (Refer to Fig. 4-4 ).Every measuring point is placed at the center of each measuring area.
www..com
Luminance Uniformity (Yu) =
L-------Active area length
B min B max
W----- Active area width
L W/6 L/6 L/3 L/3
W W/3
Fig. 4-4 Definition of measuring points Bmax: The measured maximum luminance of all measurement position. Bmin: The measured minimum luminance of all measurement position. The copyright belongs to InnoLux. Any unauthorized use is prohibited.
W/3
INNOLUX 5. Reliability Test Items
(Note3)
www..com
SPEC NO.: A070-83-TT-11 PAGE: 16/20
Item Ta = 80 Ta = -30 Ts = 70 Ta =-20
Test Conditions 240 hrs 240hrs 240hrs 240hrs 240 hrs
Remark Note 1 Note 1 Note 2 Note 1,Note 4 Note 4
High Temperature Storage Low Temperature Storage High Temperature Operation Low Temperature Operation Operate at High Temperature and Humidity Thermal Shock
+40, 90%RH max.
-30/30 min ~ +80/30 min for a total 100 cycles, Start with cold temperature and end with high temperature. Frequency range:10~55Hz Stroke:1.5mm Sweep:10Hz~55Hz~10Hz 2 hours for each direction of X. Y. Z. (6 hours for total) 100G 6ms,X, Y, Z 3 times for each direction Random Vibration : 0.015G*G/Hz from 5-200HZ, -6dB/Octave from 200-500HZ 2 hours for each direction of X. Y. Z. (6 hours for total) Height:60 cm 1 corner, 3 edges, 6 surfaces 2KV, Human Body Mode, 100pF/1500
Note 4
Vibration Test
Mechanical Shock
Package Vibration Test
Package Drop Test Electro Static Discharge
Note 1: Ta is the ambient temperature of samples. Note 2: Ts is the temperature of panel's surface. Note 3: In the standard condition, there shall be no practical problem that may affect the display function. After the reliability test, the product only guarantees operation, but doesn't guarantee all the cosmetic specification. Note 4: Before cosmetic and function test, the product must have enough recovery time, at least 2 hours at room temperature.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX 6. General Precautions
www..com
SPEC NO.: A070-83-TT-11 PAGE: 17/20
6.1.
Safety
Liquid crystal is poisonous. Do not put it in your mouth. If liquid crystal touches your skin or clothes, wash it off immediately by using soap and water.
6.2.
Handling
1. The LCD panel is plate glass. Do not subject the panel to mechanical shock or to excessive force on its surface. 2. The polarizer attached to the display is easily damaged. Please handle it carefully to avoid scratch or other damages. 3. To avoid contamination on the display surface, do not touch the module surface with bare hands. 4. Keep a space so that the LCD panels do not touch other components. 5. Put cover board such as acrylic board on the surface of LCD panel to protect panel from damages. 6. Transparent electrodes may be disconnected if you use the LCD panel under environmental conditions where the condensation of dew occurs. 7. Do not leave module in direct sunlight to avoid malfunction of the ICs.
6.3.
Static Electricity
1. Be sure to ground module before turning on power or operating module. 2. Do not apply voltage which exceeds the absolute maximum rating value.
6.4.
Storage
1. Store the module in a dark room where must keep at 2510 and 65%RH or less. 2. Do not store the module in surroundings containing organic solvent or corrosive
gas. 3. Store the module in an anti-electrostatic container or bag.
6.5.
Cleaning
1. Do not wipe the polarizer with dry cloth. It might cause scratch. 2. Only use a soft sloth with IPA to wipe the polarizer, other chemicals might permanent damage to the polarizer.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX 7. Mechanical Drawing
www..com
SPEC NO.: A070-83-TT-11 PAGE: 18/20
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX 8. Package Drawing
www..com
SPEC NO.: A070-83-TT-11 PAGE: 19/20
8.1.
Packaging Material Table
Model (Material) AT070TN83 V.1 BC Corrugated Paper BC Corrugated Paper BC Corrugated Paper PE PE Corrugated paper Dimensions(mm) 165X104X5.5 512 X 349 X 226 512X162 510 X 343 700X530 180 X 160 X 0.05 530 X 355 X 255 Unit Weight (kg) 0.130 1.466 0.046 0.130 0.048 0.002 1.100 Quantity 50pcs 1 set 4 set 1pcs 1 pcs 50 pcs 1 pcs Remark
No. 1 2 3 4 5 6 7 8
Item LCM Module Partition Corrugated Bar Corrugated Board Dust-Proof Bag A/S Bag Carton Total weight
9 . 5 28 K g 5 %
8.2.
Packaging Quantity
Partition 2 Rows x quantity per Row 25 = 50
Total LCM quantity in Carton: no. of
The copyright belongs to InnoLux. Any unauthorized use is prohibited.
INNOLUX
8.3. Packaging Drawing
SPEC NO.: A070-83-TT-11 PAGE: 20/20
www..com
The copyright belongs to InnoLux. Any unauthorized use is prohibited.


▲Up To Search▲   

 
Price & Availability of AT070TN83V1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X